tensile bond strength of hydroxyethyl methacrylate (hema) bonding agent to bovine dentine surface at various humidity
Clicks: 297
ID: 128917
2006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
297 views
56 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #40 of 127 articles by views in industrial crops and products
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 127 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
One factor that make bonding agent adhere to dentine surface maximally is the humidity condition around the dentine surface. The best bond strength between bonding agent with dentine surface is depending on the moist surface. It mean that the dentine surface should neither too dry or wet. The objective of this research is to know the tensile bond strength of hydroxyethyl methacrylate (HEMA) bonding agent to bovine dentine surface at various humidity. The bovine dentine was grounded to give flat surface, which was then etched with 37% phosphoric acid for 15 seconds. Dentine was washed with 20 ml water and dried with blot dry technique. The dentine, except the control group, was placed in a desiccator for one hour at difference humidity. Dentin was removed from desiccator, then covered with bonding agent and put into tensile tool plunger. Self-cured acrylic resin was applied on this bonding agent layer, which was placed on opposite-plunger. After 24 hours, tensile bond strength was measured with Autograph instrument. Data was statistically analyzed with One-Way ANOVA at 95% confidence level, continued with LSD test. Results of this study showed that 60%–90% humidity gave produce the lower of tensile bond strength of bonding agent to dentine surface (p ≤ 0.05). In conclusion, the treatment in 60% humidity gave the greatest tensile bond strength.
| Reference Key |
soetojo2006dentaltensile
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Adioro Soetojo |
| Journal | industrial crops and products |
| Year | 2006 |
| DOI |
10.20473/j.djmkg.v39.i2.p59-62
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.