Assessing the Potential Deployment of Biosensors for Point-of-Care Diagnostics in Developing Countries: Technological, Economic and Regulatory Aspects

Clicks: 402
ID: 12863
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1 of 94 articles by views in Biosensors

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Infectious diseases and antimicrobial resistance are major burdens in developing countries, where very specific conditions impede the deployment of established medical infrastructures. Since biosensing devices are nowadays very common in developed countries, particularly in the field of diagnostics, they are at a stage of maturity at which other potential outcomes can be explored, especially on their possibilities for multiplexing and automation to reduce the time-to-results. However, the translation is far from being trivial. In order to understand the factors and barriers that can facilitate or hinder the application of biosensors in resource-limited settings, we analyze the context from several angles. First, the technology of the devices themselves has to be rethought to take into account the specific needs and the available means of these countries. For this, we describe the partition of a biosensor into its functional shells, which define the information flow from the analyte to the end-user, and by following this partition we assess the strengths and weaknesses of biosensing devices in view of their specific technological development and challenging deployment in low-resource environments. Then, we discuss the problem of cost reduction by pointing out transversal factors, such as throughput and cost of mistreatment, that need to be re-considered when analyzing the cost-effectiveness of biosensing devices. Beyond the technical landscape, the compliance with regulations is also a major aspect that is described with its link to the validation of the devices and to the acceptance from the local medical personnel. Finally, to learn from a successful case, we analyze a breakthrough inexpensive biosensor that is showing high potential with respect to many of the described aspects. We conclude by mentioning both some transversal benefits of deploying biosensors in developing countries, and the key factors that can drive such applications.
Reference Key
migliozzi2018assessingbiosensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Migliozzi, Daniel;Guibentif, Thomas;
Journal Biosensors
Year 2018
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.