Non-Technical Loss Detection in Power Grids with Statistical Profile Images Based on Semi-Supervised Learning.
Clicks: 264
ID: 128215
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
264 views
36 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #977 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In order to keep track of the operational state of power grids, the world's largest sensor system, smart grid, was built by deploying hundreds of millions of smart meters. Such a system makes it possible to discover and make quick response to any hidden threat to the entire power grid. Non-technical losses (NTLs) have always been a major concern for their consequent security risks as well as immeasurable revenue loss. However, various causes of NTL may have different characteristics reflected in the data. Accurately capturing these anomalies faced with such a large scale of collected data records is rather tricky as a result. In this paper, we proposed a new methodology of detecting abnormal electricity consumptions. We did a transformation of the collected time-series data which turns it into an image representation that could well reflect users' relatively long term consumption behaviors. Inspired by the excellent neural network architecture used for objective detection in computer vision, we designed our deep learning model that takes the transformed images as input and yields joint features inferred from the multiple aspects the input provides. Considering the limited amount of labeled samples, especially the abnormal ones, we used our model in a semi-supervised fashion that was brought about in recent years. The model is tested on samples which are verified by on-field inspections and our method showed significant improvement for NTL detection compared with the state-of-the-art methods.
| Reference Key |
li2019nontechnicalsensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Li, Jiangteng;Wang, Fei; |
| Journal | sensors |
| Year | 2019 |
| DOI |
E236
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.