Development and Validation of a Deep Learning Algorithm for Auto-delineation of Clinical Target Volume and Organs at Risk in Cervical Cancer Radiotherapy.
Clicks: 211
ID: 128172
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
211 views
21 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #7 of 8 articles by views in Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The delineation of the clinical target volume (CTV) is a crucial, laborious and subjective step in cervical cancer radiotherapy. The aim of this study was to propose and evaluate a novel end-to-end convolutional neural network (CNN) for fully automatic and accurate CTV in cervical cancer.A total of 237 computed tomography (CT) scans of patients with locally advanced cervical cancer were collected and evaluated. A novel 2.5D CNN network, called DpnUNet, was developed for CTV delineation and further applied for CTV and organ-at-risk (OAR) delineation simultaneously. Comprehensive comparisons and experiments were performed. The mean Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (95HD) and subjective evaluation were used to assess the performance of this method.The mean DSC and 95HD values were 0.86 and 5.34mm for the delineated CTVs. The clinical experts' subjective assessments showed that 90% of the predicted contours were acceptable for clinical usage. The mean DSC and 95HD values were 0.91 and 4.05mm for bladder, 0.85 and 2.16mm for bone marrow, 0.90 and 1.27mm for left femoral head, 0.90 and 1.51mm for right femoral head, 0.82 and 4.29mm for rectum, 0.85 and 4.35mm for bowel bag, 0.82 and 4.96mm for spinal cord respectively. The average delineation time for one patient's CT images was within 15 seconds.The experimental results demonstrate that the CTV and OARs delineated for cervical cancer by DpnUNet was in close agreement with the ground truth. DpnUNet could significantly reduce the radiation oncologists' contouring time.
| Reference Key |
liu2020developmentradiotherapy
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liu, Zhikai;Liu, Xia;Guan, Hui;Zhen, Hongan;Sun, Yuliang;Chen, Qi;Chen, Yu;Wang, Shaobin;Qiu, Jie; |
| Journal | Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology |
| Year | 2020 |
| DOI |
S0167-8140(20)30835-5
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.