Pt-poly(L-lactic acid) microelectrode-based microsensor for in situ glucose detection in sweat.

Clicks: 287
ID: 128083
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #37 of 85 articles by views in Biosensors & bioelectronics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A miniaturized biosensor was developed for in situ noninvasive detection of glucose in sweat. The biosensor was composed of a pair of interdigital Pt-poly(L-lactic acid) (Pt-PLA) microelectrode arrays operating as the working and auxiliary electrode. The size of the sensor was 3.56 × 0.72 mm, while the width of the interdigital microelectrodes was 2.4 μm. The microelectrodes with densely packed coral-like Pt-PLA nanoparticles were fabricated using a multi-potential step deposition process. We investigated the influence of the Pt-PLA electrodeposition time on the morphology and electrochemical performance of the microelectrode. The optimized biosensor exhibited high electrocatalytic activity because of the synergistic effects between the Pt nanoparticles and PLA polymer matrix, including the electrooxidation of Pt on glucose, the adsorption of glucose by the PLA polymer, and the acceleration of the glucose dehydrogenation step. For glucose detection in sweat and tears, the linear concentration ranges were observed to be 0.001-33.76 μM and 33.76-1000 μM, with a low detection limit of 0.19 nM. The miniaturized biosensor exhibited high sensitivity and signal stability, and could be suitable for use in the long-term monitoring of sweat glucose levels in patients, athletes, and other subjects in various difficult environments.
Reference Key
han2020ptpolyllacticbiosensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Han, JingYi;Li, Mingji;Li, Hongji;Li, Cuiping;Ye, Jianshan;Yang, Baohe;
Journal Biosensors & bioelectronics
Year 2020
DOI
S0956-5663(20)30664-3
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.