Revisiting the bioelectrochemical system based biosensor for organic sensing and the prospect on constructed wetland-microbial fuel cell.
Clicks: 256
ID: 128072
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
256 views
43 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #223 of 409 articles by views in Chemosphere
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 409 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Bioelectrochemical system (BES) based biosensors for organic sensing has long been investigated. However, there is no uniform criterion to evaluate directly the performance of the BES based biosensors due to their different scale. Here, for the first time, we show that the normalized maximum detection range (NMDR) and normalized sensing time (NST) can potentially be used as the two criteria in BES based biosensors for organic sensing. Thereafter, the recently emerged, relatively larger scale BES (i.e. constructed wetland-microbial fuel cell, CW-MFC) was specifically examined in this study. The biocathode formation and the influence of anodic material on sensor performance were systematically evaluated. The system with metal-based anode was found to produce a more stable and quicker response (low NST) than that with carbon-based anode. Significantly, the continuous loading mode was found to greatly reduce the NMDR compared to the batch mode, and the hydraulic residence time (HRT) is the critical factor determining the NMDR. Furthermore, it was found that the electrical signals generated from the CW-MFC system were insignificantly influenced by some specific chemical disturbances, such as Cu and herbicide. Therefore, normalized toxicity (NT) is suggested to be considered in BES based biosensor. However, for chemicals with higher reduction potentials (NO in this work), the system presented a high response, enabling its potential for monitoring NO in effluents or groundwater. This study can hopefully contribute to further development of the sustainable BES based biosensors in CW.
| Reference Key |
xu2020revisitingchemosphere
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Xu, Lei;Yu, Wenzheng;Graham, Nigel;Zhao, Yaqian; |
| Journal | Chemosphere |
| Year | 2020 |
| DOI |
S0045-6535(20)32727-2
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.