Sensitive electrochemiluminescent immunosensor for diabetic nephropathy analysis based on tris(bipyridine) ruthenium(II) derivative with binary intramolecular self-catalyzed property.

Clicks: 303
ID: 12711
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #31 of 85 articles by views in Biosensors & bioelectronics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Electrochemiluminescence (ECL) co-reaction and ECL resonance energy transfer (ECL-RET) are two main methods for enhancing the ECL efficiency. In this work, a novel tris(bipyridine) ruthenium(II) derivative (Ru(bpy)(mcbpy)-PEI-ABEI) with high ECL efficiency due to the binary intramolecular ECL self-catalyzed property including intramolecular co-reaction and intramolecular ECL-RET, was prepared for the construction of immunosensor. Firstly, through intramolecular co-reaction, polyethyleneimine (PEI) with large amount of amine co-reactive groups (primary, secondary and tertiary amine) not only increased the ECL intensity of Ru(bpy)(mcbpy), but also improved the ECL signal of N-(aminobutyl)-N-(ethylisoluminol) (ABEI). Meanwhile, ABEI, as an effective energy transfer donor, could further increase the ECL intensity of Ru(bpy)(mcbpy) (as energy transfer receptor) by intramolecular ECL-RET. It is worth noting that the strategy combined intramolecular co-reaction and intramolecular ECL-RET in the same ECL process was more effective for ECL efficiency enhancement compared with the traditional intermolecular interaction or individual intramolecular interaction, which would improve the sensitivity of immunosensor obviously. Thus, the proposed signal-on ECL immunosensor using convex hexoctahedral Pd@Au core-shell nanocrystals (Pd-Au HCDs) as immobilized platform exhibited a detected range for collagen type IV (Col IV), a typical biomarker of diabetic nephropathy (DN), from 0.5pgmL to 7.2ngmL with an estimated detection limit of 0.17pgmL. The developed strategy combined intramolecular co-reaction with intramolecular ECL-RET offered an effective mean for ECL methodology in ECL efficency enhancement and also provided possible road for early diagnosis and treatment monitoring of DN.
Reference Key
wang2018sensitivebiosensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wang, Haijun;Chai, Yaqin;Li, Hang;Yuan, Ruo;
Journal Biosensors & bioelectronics
Year 2018
DOI
S0956-5663(17)30590-0
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.