Extraction spectrophotometric determination of aluminum in dialysis concentrates with 3,5-ditertbutylsalicylfluorone and ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate

Clicks: 427
ID: 1262
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #8 of 235 articles by views in Journal of pharmaceutical and biomedical analysis

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The paper describes a highly sensitive and selective extraction spectrophotometric method for determination of aluminum in dialysis concentrates with new reagent 3,5-ditertbutylsalicylfluorone abbreviated as DTBSF, in which the ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate abbreviated as [C4tmsim][PF6] was used as novel medium for liquid/liquid extraction of aluminum(III). Under optimal condition, DTBSF reacted with aluminum(III) to form a neutral Al–DTBSF complex rapidly, the complex was then extracted into the [C4tmsim][PF6] phase, the absorbance of the complex in ionic liquid at 542nm was recorded and used to determine aluminum(III). The apparent molar absorptivity of the complex and detection limit were found to be 3.52×106lmol−1cm−1 and 0.06ÎŒg/l, respectively. The absorbance of the complex at 542nm increases linearly with the concentration of aluminum(III) up to 3ÎŒg of aluminum(III) in 250ml of aqueous solution. The interference study show the determination of aluminum is free from interferences of almost all positive and negative ions found in dialysis concentrate samples. The determination of aluminum in dialysis concentrates were carried out by the present method and electrothermal atomic absorption spectrometry (GTAAS). The results were satisfactorily comparable so that the applicability of the proposed method with the ionic liquid system was also investigated. Moreover, the synthesis of and conditions for the formation and extraction of Al–DTBSF complex were investigated as well.
Reference Key
zaijun2007extraction Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zaijun Li;Naping Lu;Xia Zhou;Qijun Song
Journal Journal of pharmaceutical and biomedical analysis
Year 2007
DOI
https://doi.org/10.1016/j.jpba.2006.11.032
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.