An Exploration of Factors Affecting Deposition of Pharmaceutical Aerosols in the Alberta Idealized Throat.
Clicks: 308
ID: 12569
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
75.3
/100
308 views
227 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 4 articles by views in journal of aerosol medicine and pulmonary drug delivery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The development of accurate correlations requires the consideration of a number of factors , including the emulation of upper airway geometry, inhalation maneuver, inhaler orientation, and environmental conditions. In this study, we examine the effects of inhaler insertion angle and humidity on deposition from a number of marketed inhalers. Three dry-powder inhalers (DPIs; Pulmicort Turbuhaler, Budelin Novolizer, and Easyhaler Budesonide) were examined at two insertion angles, one with the inhaler directed toward the back of the oral cavity, the other with the inhaler directed toward the tongue. Three pressurized metered-dose inhalers (pMDIs; QVAR, Ventolin Evohaler, and Flovent HFA) were examined considering the joint effects of insertion angle (as above) and relative humidity at low (15%-25%) and high (>95%) conditions. Deposited drug masses in an Alberta Idealized Throat and downstream filter were quantified through ultraviolet spectroscopy. Three of six inhalers showed sensitivity to insertion angle. When directed toward the tongue versus the back of the mouth, the filter dose decreased from 21.9% to 15.6% (percent delivered dose) for Easyhaler Budesonide ( < 0.001), from 46.5% to 26.0% for Ventolin Evohaler ( < 0.001), and from 56.7% to 35.7% for Flovent HFA ( < 0.001) for tests at ambient laboratory humidity. Sensitivity to insertion angle and increases in total lung dose variability may be reduced in future products using larger diameter mouthpieces and smaller particles for DPIs and lower-momentum sprays for pMDIs. Humidity influenced deposition from Ventolin Evohaler and Flovent HFA. When oriented toward the back of the oral cavity, the filter dose decreased from 46.5% to 36.9% for Ventolin Evohaler ( = 0.005) and from 56.7% to 44.2% for Flovent HFA ( < 0.001) at high humidity relative to low. High humidity may cause a reduction in total lung doses for some pMDI aerosols.
| Reference Key |
ruzycki2019anjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ruzycki, Conor A;Martin, Andrew R;Finlay, Warren H; |
| Journal | journal of aerosol medicine and pulmonary drug delivery |
| Year | 2019 |
| DOI |
10.1089/jamp.2019.1531
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.