Review of the dioxin problem. Mass spectrometric analyses of tetrachlorodioxins in environmental samples.
Clicks: 282
ID: 1241
1980
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
66.4
/100
282 views
217 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #1 of 12 articles by views in biomedical mass spectrometry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Major concern over the chemical group of chlorodioxins has arisen since 2,3,7,8-tetrachlorodibenzo-p-dioxin with its extremely toxic and teratogenic properties has been found in widely distributed pesticides such as the herbicide 2,4,5-trichlorophenoxy acetic acid. Because of its chemical stability and lipophilic nature, 2,3,7,8-tetrachlorodibenzo-p-dioxin released into the environment has the potential of accumulation in the food chain. Mass spectrometry in its various forms has been the method of choice to detect and confirm low parts per billion of 2,3,7,8-tetrachlorodibenzo-p-dioxin. Recently, a Consensus Forum held at the National Center for Toxicological Research amongst the various United States Government agencies (Food and Drug Administration, Environmental Protection Agency, US Department of Agriculture and National Institute of Environmental Health Sciences), eloquently demonstrated the potential, as well as the shortcomings, of the various techniques applied. In particular, the availability of a stable 13C labeled 2,3,7,8-tetrachlorodibenzo-p-dioxin has proved to be an essential component to achieve low level quantitation. A brief review of the findings of the Consensus Forum is presented together with a detailed survey of the application of atmospheric pressure ionization mass spectrometry to TCDD analysis at the National Center for Toxicological Research/Food and Drug Administration.
| Reference Key |
cairns1980review
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Cairns, T;Fishbein, L;Mitchum, R K; |
| Journal | biomedical mass spectrometry |
| Year | 1980 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.