Effects of aeration on microbes and intestinal bacteria in bioaerosols from the BRT of an indoor wastewater treatment facility.

Clicks: 339
ID: 12260
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #154 of 637 articles by views in The Science of the total environment

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 637 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The generation and emission of airborne bacteria from a biochemical reaction tank (BRT) for wastewater treatment was investigated by altering the aeration rate. The levels of bioaerosols increased from 715 ± 69 to 1597 ± 135 CFU/m (total airborne bacteria) and from 78 ± 6 to 359 ± 18 CFU/m (intestinal bacteria) as the aeration rate increased from 0.3 to 1.2 m/h. Most airborne bacteria were attached to particles smaller than 4.7 μm at an aeration rate of 0.3 m/h. They were found attached to larger particles (>4.7 μm) when the aeration rate increased to 1.2 m/h. A similar phenomenon was observed for intestinal bacteria. The high-throughput sequencing technique was used to assay the microbial populations of the bioaerosols. Both microbial counts and diversity increased as the aeration rate increased. Brevundimonas (63.82%), Chryseobacterium (16.54%), and Micrococcaceae (12.37%) were the dominant intestinal bacteria at an aeration rate of 0.3 m/h. Pseudochrobactrum (33.10%), Citrobacter (21.28%), and Yersinia (18.21%) were the dominant intestinal bacteria at an aeration rate of 1.2 m/h. The level, particle size distribution, population structure, and diversity of the bioaerosols were all affected by aeration rate. The source tracker results indicated that water and the surrounding air were the two main bioaerosol sources. The contribution of water is greater at larger levels of aeration. Inhalation was the main pathway of microbial aerosol intake for people in the surrounding area. The exposure hazard quotients for adult males were generally higher than those for adult females. Necessary measures should be taken to ensure worker safety.
Reference Key
wang2019effectsthe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wang, Yanjie;Li, Lin;Xiong, Ren;Guo, Xuesong;Liu, Junxin;
Journal The Science of the total environment
Year 2019
DOI
S0048-9697(18)33208-X
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.