Emission characteristics and exposure assessment of particulate matter and polybrominated diphenyl ethers (PBDEs) from waste printed circuit boards de-soldering.
Clicks: 337
ID: 12257
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
72.9
/100
337 views
274 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #155 of 637 articles by views in The Science of the total environment
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 637 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Heating processes for the removal of electronic components from waste printed circuit boards (WPCBs) is an important step in the chain of electronic waste recycling, and toxic fumes are generated during the de-soldering process, causing environmental pollution and posing health risks for the workers. This study is aimed to characterize emission and deposition fluxes of respirable particulate matter (PM), and assess exposure of workers to particle-bound polybrominated diphenyl ethers (PBDEs). An electrical low-pressure impactor was used to measure the real-time PM concentrations inside and outside the hood during the WPCBs de-soldering process. The results show that PM mass concentration inside the hood (204 mg/m) was significantly higher than outside the hood (9.4 mg/m), representing 95.4% PM removal by the hood. According to the International Commission on Radiological Protection model, the total deposition fluxes of PM in head airways region, tracheobronchial region, and alveolar region were determined as 1930, 74.0, and 123 μg/h, respectively. The deposition flux for coarse particles (2.5-10 μm) in the head airways was the largest (1830 μg/h), accounting for 86.1% of total PM deposited in respiratory system. The ∑PBDEs concentration in PM inside the WPCBs de-soldering workshop was 20,300 pg/m, and the ∑PBDEs inhalation exposure for the worker was 1.46 ng/kg/day. This study improves understanding of PM emission mechanisms and provides fundamental data for health assessments during WPCBs de-soldering process.
| Reference Key |
guo2019emissionthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Guo, Jie;Ji, Ang;Wang, Jianbo;Ogunseitan, Oladele A;Xu, Zhenming; |
| Journal | The Science of the total environment |
| Year | 2019 |
| DOI |
S0048-9697(19)30195-0
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.