Air Quality and Employee Hygiene-related Behavior in a Post Anesthesia Care Unit in Thailand.
Clicks: 360
ID: 12251
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
74.4
/100
360 views
263 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #3 of 30 articles by views in Asian/Pacific Island nursing journal
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Post anesthesia care units (PACU) are sanitary spaces at hospitals. Bacterial and fungal contaminants in ambient air can pose significant threats to patient recovery. Excess waste anesthetic gases such as nitrous oxide and desflurane can also pose reproductive, genetic, and other health risks to PACU staff who suffer longterm exposure. Healthcare institutions routinely monitor and study PACU air quality as required by occupational health and safety acts and related regulations, and professional standards of care. This study presents recent data from a PACU intervention at Rajavithi Hospital in Bangkok, Thailand. Rajavithi took measurements of concentrations of airborne fungi, bacteria, desflurane, and nitrous oxide before and after installation of a new ventilation system. Concurrently, the hospital surveyed employees before and after a hazard communication and conducted a training campaign in efforts to understand employee attitudes toward health and safety procedures, and to increase their perceived importance of several PACU-specific protocols. Results showed bacterial contamination fell from 1,307 CFU/m to 182 CFU/m, fungi fell from 70.4 CFU/m to 35.8 CFU/m, desflurane fell from 0.25 ppm to 0.21 ppm, and nitrous oxide fell from 21.86 ppm to 20.47 ppm during the intervention while PACU worker attitudes toward health and safety improved. Additional monitoring, communication, and training are recommended for Rajavithi and other healthcare institutions.
| Reference Key |
kampan2019airasianpacific
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kampan, Somphorn; |
| Journal | Asian/Pacific Island nursing journal |
| Year | 2019 |
| DOI |
10.31372/20190401.1005
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org