Rapid urinary antigen test for diagnosis of pneumococcal community-acquired pneumonia in adults
Clicks: 124
ID: 118425
2003
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
30.0
/100
124 views
26 readers
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #3 of 5 articles by views in european respiratory journal
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Streptococcus pneumoniae is suspected to cause an important proportion of community-acquired pneumonia (CAP) whose aetiology cannot be detected with conventional tests.
In this study, the authors evaluated the diagnostic yield of a new immunochromatographic membrane test (ICT) for the detection of the S. pneumoniae antigen in the urine of patients admitted with diagnosed CAP. ICT was performed in unconcentrated and concentrated urine from all the patients. ICT was repeated 1 month after discharge in a group initially testing positive. The authors also studied the ICT in clinically stable human immunodeficiency virus type 1 (HIV1)-infected patients.
S. pneumoniae antigen was detected in all of the 68 (100%) patients tested with definitive pneumococcal pneumonia. In five of these cases ICT was only positive when it had been performed on the patients. The S. pneumoniae antigen was also detected in 36 (69.2%) of 52 patients with probable pneumococcal pneumonia and in 50 of 277 (18%) patients without pneumococcal pneumonia. ICT remained positive in 16 (69.5%) of 23 patients, 1 month after hospital discharge. Nasopharyngeal colonisation with S. pneumoniae was detected in 8 (12%) of 68 clinically stable HIV1 infected patients, but none tested ICT positive.
The Binax NOW® immunochromatographic membrane test is a rapid, sensitive and specific test for detecting pneumococcal community-acquired pneumonia in adults. The test may remain positive for several weeks after pneumococcal pneumonia.
This work was supported by grants from the following: Sociedad Española de Neumología y Cirugía Torácica (SEPAR), Spanish Ministry of Health (FIS 00/0505), FUCAP (Maria Ravá), and Binax Inc (Portland, ME, USA).
| Reference Key |
marcos2003europeanrapid
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | M.A. Marcos;M.T. Jiménez de Anta;J.P. de la Bellacasa;J. González;E. Martínez;E. García;J. Mensa;A. de Roux;A. Torres;M.A. Marcos;M.T. Jiménez de Anta;J.P. de la Bellacasa;J. González;E. Martínez;E. García;J. Mensa;A. de Roux;A. Torres; |
| Journal | european respiratory journal |
| Year | 2003 |
| DOI |
10.1183/09031936.03.00058802
|
| URL | |