CT portography by direct intrasplenic contrast injection: a new technique

Clicks: 208
ID: 118156
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #54 of 69 articles by views in abdominal imaging

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: The evaluation of percutaneous contrast injection into splenic parenchyma as an alternative technique for computed tomographic (CT) portography in the preoperative assessment of primary hepatobiliary tumors. Methods: Thirty-two patients underwent a nonenhanced CT scan of the liver, after which a 19-gauge, 10-cm-long needle was introduced into the splenic parenchyma under CT guidance. One hundred forty milliliters of contrast medium (200 mgI/mL; 28 g/I) were injected through this needle: first, a 20-mL bolus (in 5 s) and then 2 mL/s for 60 s. At the end of the bolus injection (5 s), 8-mm-thick contiguous axial scans of the liver were obtained. Results: The success rate of the procedure was 93.7% (30/32; two technical failures). The average time required for the entire study was 13 min and 50 s (range = 7 min 53 s to 25 min 17 s). Hepatic parenchymal enhancement was good in 24/30 (80%), moderate in 3/30 (10%), and unsatisfactory in caudal sections of the liver in 3/30 (10%). Artifactual perfusion defects were seen in 4/30 (13%) due to inadvertant injection of small quantities of air. Intrasplenic subcapsular contrast accumulation occurred in 56.2% (18/32; minimal 15, moderate 3), extrasplenic contrast leakage in 12.5% (4/32), and left shoulder pain in 18.7% (6/32). No major complications were observed. Conclusions: Direct intrasplenic contrast injection for CT portography is a simple, effective, and safe technique with a high success rate and requires significantly less time and lower doses of contrast medium; it also eliminates angiography, indwelling arterial catheters, and patient transfers from angiography to the CT area.
Reference Key
jain2014abdominalct Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors R. Jain;S. Sawhney;P. Sahni;K. Taneja;M. Berry;R. Jain;S. Sawhney;P. Sahni;K. Taneja;M. Berry;
Journal abdominal imaging
Year 2014
DOI
doi:10.1007/s002619900494
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.