Surgical performance when inserting non-locking screws: a systematic review.
Clicks: 325
ID: 117295
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
62.9
/100
325 views
205 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 3 articles by views in EFORT open reviews
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Billions of screws are inserted by surgeons each year, making them the most commonly inserted implant. When using non-locking screws, insertion technique is decided by the surgeon, including how much to tighten each screw. The aims of this study were to assess, through a systematic review, the screw tightness and rate of material stripping produced by surgeons and the effect of different variables related to screw insertion.Twelve studies were included, with 260 surgeons inserting a total of 2793 screws; an average of 11 screws each, although only 1510 screws have been inserted by 145 surgeons where tightness was measured - average tightness was 78±10% for cortical (n = 1079) and 80±6% for cancellous screw insertions (n = 431).An average of 26% of all inserted screws irreparably damaged and stripped screw holes, reducing the construct pullout strength. Furthermore, awareness of bone stripping is very poor, meaning that screws must be considerably overtightened before a surgeon will typically detect it.Variation between individual surgeons' ability to optimally insert screws was seen, with some surgeons stripping more than 90% of samples and others hardly any. Contradictory findings were seen for the relationship between the tightness achieved and bone density.The optimum tightness for screws remains unknown, thus subjectively chosen screw tightness, which varies greatly, remains without an established target to generate the best possible construct for any given situation. Work is needed to establish these targets, and to develop methods to accurately and repeatably achieve them. Cite this article: EFORT Open Rev 2020;5:26-36. DOI: 10.1302/2058-5241.5.180066.
| Reference Key |
whitehouse2020efortsurgical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | James W. A. Fletcher,Lisa Wenzel,Verena Neumann,Geoff Richards,Boyko Gueorguiev,Harinderjit S. Gill,Ezio Preatoni,Michael R. Whitehouse;James W. A. Fletcher;Lisa Wenzel;Verena Neumann;Geoff Richards;Boyko Gueorguiev;Harinderjit S. Gill;Ezio Preatoni;Michael R. Whitehouse; |
| Journal | EFORT open reviews |
| Year | 2020 |
| DOI |
10.1302/2058-5241.5.180066
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.