Development of Two Novel Hybrid Prediction Models Estimating Ultimate Bearing Capacity of the Shallow Circular Footing
Clicks: 292
ID: 117193
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
292 views
41 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #45 of 187 articles by views in applied sciences
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 187 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In the present work, we employed artificial neural network (ANN) that is optimized with two hybrid models, namely imperialist competition algorithm (ICA) as well as particle swarm optimization (PSO) in the case of the problem of bearing capacity of shallow circular footing systems. Many types of research have shown that ANNs are valuable techniques for estimating the bearing capacity of the soils. However, most ANN training models have some drawbacks. This study aimed to focus on the application of two well-known hybrid ICA–ANN and PSO–ANN models to the estimation of bearing capacity of the circular footing lied in layered soils. In order to provide the training and testing datasets for the predictive network models, extensive finite element (FE) modelling (a database includes 2810 training datasets and 703 testing datasets) are performed on 16 soil layer sets (weaker soil rested on stronger soil and vice versa). Note that all the independent variables of ICA and PSO algorithms are optimized utilizing a trial and error method. The input includes upper layer thickness/foundation width (h/B) ratio, footing width (B), top and bottom soil layer properties (e.g., six of the most critical soil characteristics), vertical settlement of circular footing (s), where the output was taken ultimate bearing capacity of the circular footing (Fult). Based on coefficient of determination (R2) and Root Mean Square Error (RMSE), amounts of (0.979, 0.076) and (0.984, 0.066) predicted for training dataset and amounts of (0.978, 0.075) and (0.983, 0.066) indicated in the case of the testing dataset of proposed PSO–ANN and ICA–ANN models of prediction network, respectively. It demonstrates a higher reliability of the presented PSO–ANN model for predicting ultimate bearing capacity of circular footing located on double sandy layer soils.
| Reference Key |
moayedi2019applieddevelopment
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Hossein Moayedi;Bahareh Kalantar;Anastasios Dounis;Dieu Tien Bui;Loke Kok Foong;Moayedi, Hossein;Kalantar, Bahareh;Dounis, Anastasios;Tien Bui, Dieu;Foong, Loke Kok; |
| Journal | applied sciences |
| Year | 2019 |
| DOI |
10.3390/app9214594
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org