Measuring the14C content in liquid scintillators

Clicks: 244
ID: 116799
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #321 of 935 articles by views in journal of physics: conference series

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 935 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We are going to perform a series of measurements where the 14C/12 C ratio will be measured from several liquid scintillator samples with a dedicated setup. The setup is designed with the aim of measuring ratios smaller than 10-18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia and in the Pyhäsalmi mine, Finland. In Baksan the measurements started in 2015 and in Pyhäsalmi they start in the beginning of 2015. In order to fully understand the operation of the setup and its background contributions a development of simulation packages has also been started. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic 14C content in the liquid is extremely low. In the Borexino CTF detector at Gran Sasso, Italy the 14C/12C ratio of 2 × 10-18 has been achieved being the lowest 14C concentration ever measured. In principle, the older the oil or gas source that the liquid scintillator is derived of and the deeper it situates, the smaller the 14C/12C ratio is supposed to be. This, however, is not generally the case, and the ratio is probably determined by the U and Th content of the local environment.
Reference Key
zavarzina2016journalmeasuring Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors T. Enqvist,I R Barabanov,L B Bezrukov,A M Gangapshev,Y M Gavrilyuk,V Yu Grishina,V I Gurentsov,J Hissa,J Joutsenvaara,V V Kazalov,S Krokhaleva,J Kutuniva,P Kuusiniemi,V V Kuzminov,A S Kurlovich,K Loo,B K Lubsandorzhiev,S Lubsandorzhiev,V P Morgalyuk,G Y Novikova,A M Pshukov,V V Sinev,M Słupecki,W H Trzaska,Sh I Umerov,A. V. Veresnikova,A Virkajärvi,Y A Yanovich,V P Zavarzina;T. Enqvist;I R Barabanov;L B Bezrukov;A M Gangapshev;Y M Gavrilyuk;V Yu Grishina;V I Gurentsov;J Hissa;J Joutsenvaara;V V Kazalov;S Krokhaleva;J Kutuniva;P Kuusiniemi;V V Kuzminov;A S Kurlovich;K Loo;B K Lubsandorzhiev;S Lubsandorzhiev;V P Morgalyuk;G Y Novikova;A M Pshukov;V V Sinev;M Słupecki;W H Trzaska;Sh I Umerov;A. V. Veresnikova;A Virkajärvi;Y A Yanovich;V P Zavarzina;
Journal journal of physics: conference series
Year 2016
DOI
10.1088/1742-6596/718/6/062018
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.