Pneumolysin polymerase chain reaction for diagnosis of pneumococcal pneumonia and empyema in children
Clicks: 269
ID: 116515
2006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
269 views
36 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 4 articles by views in european journal of clinical microbiology and infectious diseases
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Streptococcus pneumoniae is the most important cause of childhood pneumonia and empyema, yet the diagnosis of pneumococcal infections by conventional methods is challenging. In this study, the clinical value of the pneumolysin-targeted real-time polymerase chain reaction (PCR) method for the diagnosis of pneumococcal pneumonia and empyema was evaluated with 33 whole blood samples and 12 pleural fluid samples. The analytical sensitivity of the PCR assay was 4 fg of pneumococcal DNA, corresponding to two genome equivalents of pneumococcal DNA per reaction. The PCR assay correctly detected all clinical isolates of S. pneumoniae tested, whereas all nonpneumococcal bacterial organisms tested were negative by PCR. In a clinical trial, S. pneumoniae was detected by PCR in the pleural fluid of 75% of children with empyema, increasing the detection rate of pneumococcus almost tenfold that of pleural fluid culture. However, in whole blood samples, PCR detected S. pneumoniae in only one child with pneumonia and one child with pneumococcal empyema and failed to detect S. pneumoniae in three children with blood cultures positive for S. pneumoniae. The present data indicate that pneumolysin-targeted real-time PCR of pleural fluid is a valuable method for the etiologic diagnosis of pneumococcal empyema in children. The ease and rapidity of the LightCycler technology (Roche Diagnostics, Mannheim, Germany) make real-time PCR an applicable tool for routine diagnostics. In the evaluation of blood samples, blood culture remains the superior method for the diagnosis of bacteremic pneumococcal disease.
| Reference Key |
lahti2006europeanpneumolysin
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | E. Lahti;J. Mertsola;T. Kontiokari;E. Eerola;O. Ruuskanen;J. Jalava;E. Lahti;J. Mertsola;T. Kontiokari;E. Eerola;O. Ruuskanen;J. Jalava; |
| Journal | european journal of clinical microbiology and infectious diseases |
| Year | 2006 |
| DOI |
doi:10.1007/s10096-006-0225-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.