Photoelectrochemical immunoassay of aflatoxin B in foodstuff based on amorphous TiO and CsPbBr perovskite nanocrystals.

Clicks: 471
ID: 11640
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #8 of 50 articles by views in The Analyst

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aflatoxin B1 (AFB1) pollution is one of the most serious problems for food safety. In this paper, a split-type photoelectrochemical (PEC) immunoassay was designed for sensitive detection of AFB1 in foodstuffs by using amorphous TiO2 with all-inorganic perovskite CsPbBr3 nanocrystals (CsPbBr3/a-TiO2). The a-TiO2 layer not only improved the stability of CsPbBr3 nanocrystals, but also facilitated charge transfer, which resulted in the increasing photocurrent of the nanocomposites. Initially, a competitive-type enzyme immunoreaction was executed on a high-binding microplate between the analyte and alkaline phosphatase (ALP)-labeled AFB1-bovine serum albumin (AFB1-BSA) conjugate. Accompanied by the formation of the immunocomplex, the carried ALP triggered enzymatic hydrolysis to generate ascorbic acid (AA, as an electron donor) for increasing the photocurrent of the CsPbBr3/a-TiO2-modified electrode. Coupling with the competitive enzyme immunoassay, the photocurrent of the modified electrode decreased with the increase of target AFB1 concentration in a dynamic working range from 0.01 ng mL-1 to 15 ng mL-1 with a limit of detection (LOD) of 2.8 pg mL-1 under optimum conditions. Furthermore, the photoelectrochemical immunoassay was also utilized to detect AFB1 in peanut and corn samples, giving acceptable accuracy in comparison with the referenced AFB1 enzyme-linked immunosorbent assay (ELISA) method.
Reference Key
su2019photoelectrochemicalthe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal The Analyst
Year 2019
DOI
10.1039/c9an00994a
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.