Validity of 3-Tesla diffusion-weighted magnetic resonance imaging for distinction of reactive and metastatic lymph nodes in head-and-neck carcinoma

Clicks: 363
ID: 116299
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #38 of 148 articles by views in journal of cancer research and therapeutics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 148 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objectives: The objective was to study the relationship of 3-Tesla (3T) diffusion-weighted magnetic resonance imaging (DW-MRI) with apparent diffusion coefficient (ADC) value for distinction of reactive and metastatic lymph nodes (LNs) in head-and-neck carcinoma (HNC) patients and to determine the ADC cutoff value for metastatic LNs at various levels.Materials and Methods: 3T DW and T1- and T2-weighted imaging sequences were done in 34 patients with biopsy-proven primary HNC of 100 cervical LNs ≥1 cm in diameter. The mean ADC values were compared with histopathologically proven LNs using the independent t-test. ADC cutoff value was evaluated with sensitivity, specificity, accuracy, positive predictive value, negative predictive value and a receiver operating characteristic curve analysis.Results: The mean ADC value of reactive LN was 1.2933 × 10-3 mm2/s and metastatic LN was 0.908 × 10-3 mm2/s. An ADC cutoff value was 0.868 × 10-3 mm2/s with 84% sensitivity, 96% specificity, 93% accuracy, 87.5% positive predictive value, and 94.7% negative predictive value. A significant difference in mean ADC value between reactive and metastatic LNs was noted (P< 0.001).Conclusion: 3T DW-MRI is useful in differentiating reactive and metastatic cervical LNs in HNC patients. However, studies with larger sample size have to be performed to validate ADC threshold value with 3T DW-MRI in differentiating between reactive and metastatic LNs for clinical practice.
Reference Key
vijayalakshmi2020journalvalidity Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Vijayalakshmi;K Vijayalakshmi;PH Raghuram;K Saravanan;CL Krithika;A Kannan;
Journal journal of cancer research and therapeutics
Year 2020
DOI
0973-1482
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org