Assessment of the Levels of Airborne Bacteria, Gram-Negative Bacteria, and Fungi in Hospital Lobbies

Clicks: 272
ID: 115615
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #476 of 862 articles by views in International journal of environmental research and public health

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 862 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aims: We assessed the levels of airborne bacteria, Gram-negative bacteria (GNB), and fungi in six hospital lobbies, and investigated the environmental and hospital characteristics that affected the airborne microorganism levels. Methods: An Andersen single-stage sampler equipped with appropriate nutrition plate agar was used to collect the samples. The three types of microorganisms were repeatedly collected at a fixed location in each hospital (assumed to be representative of the entire hospital lobby) from 08:00 through 24:00, with a sampling time of less than 5 min. Temperature and relative humidity were simultaneously monitored. Results: Multiple regression analysis was used to identify the major factors affecting microorganism levels. The average levels of bacteria (7.2 × 102 CFU/m3), GNB (1.7 × 10 CFU/m3), and fungi (7.7 × 10 CFU/m3) indicated that all hospital lobbies were generally contaminated. Season was the only factor that significantly affected the levels of all microorganisms (p < 0.0001), where contamination was the highest during the summer, significantly higher than during the winter. Other significant factors varied by microorganism, as follows: airborne bacteria (number of people in the lobby, sampling time), GNB (scale of hospital), and fungi (humidity and air temperature). Conclusions: Hospital lobby air was generally contaminated with microorganisms, including bacteria, GNB, and fungi. Environmental factors that may significantly influence the airborne concentrations of these agents should be managed to minimize airborne levels.
Reference Key
park2013internationalassessment Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Dong-Uk Park;Jeong-Kwan Yeom;Won Jae Lee;Kyeong-Min Lee;Park, Dong-Uk;Yeom, Jeong-Kwan;Lee, Won Jae;Lee, Kyeong-Min;
Journal International journal of environmental research and public health
Year 2013
DOI
10.3390/ijerph10020541
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.