NIR Monitoring of Ammonia in Anaerobic Digesters Using a Diffuse Reflectance Probe

Clicks: 260
ID: 114542
2012
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
The feasibility of using a diffuse reflectance probe attached to a near infrared spectrometer to monitor the total ammonia nitrogen (TAN) content in an anaerobic digester run on cattle manure was investigated; as a previous study has indicated that this probe can be easily attached to an anaerobic digester. Multivariate modelling techniques such as partial least squares regression and interval partial least squares methods were used to build models. Various data pre-treatments were applied to improve the models. The TAN concentrations measured were in the range of 1.5 to 5.5 g/L. An R2 of 0.91 with an RMSEP of 0.32 was obtained implying that the probe could be used for monitoring and screening purposes.
Reference Key
raju2012sensorsnir Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Chitra S. Raju;Mette Marie Løkke;Sutaryo Sutaryo;Alastair J. Ward;Henrik B. Møller;Raju, Chitra S.;Løkke, Mette Marie;Sutaryo, Sutaryo;Ward, Alastair J.;Møller, Henrik B.;
Journal sensors
Year 2012
DOI
10.3390/s120202340
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.