A novel ppm-precise absolute calibration method for precision high-voltage dividers
Clicks: 305
ID: 114343
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
305 views
30 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 3 articles by views in metrologia
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The most common method to measure direct current high voltage (HV) down to the ppm-level is to use resistive high-voltage dividers. Such devices scale the HV into a range where it can be compared with precision digital voltmeters to reference voltages sources, which can be traced back to Josephson voltage standards. So far the calibration of the scale factors of HV dividers for voltages above 1~kV could only be done at metrology institutes and sometimes involves round-robin tests among several institutions to get reliable results. Here we present a novel absolute calibration method based on the measurement of a differential scale factor, which can be performed with commercial equipment and outside metrology institutes. We demonstrate that reproducible measurements up to 35~kV can be performed with relative uncertainties below $1\cdot10^{-6}$. This method is not restricted to metrology institutes and offers the possibility to determine the linearity of high-voltage dividers for a wide range of applications.
| Reference Key |
thuemmler2019metrologiaa
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Oliver Rest,Daniel Winzen,Stephan Bauer,Roland Berendes,Johann Meisner,T Thümmler,Sascha Wüstling,Christian Weinheimer,Thomas Thuemmler;Oliver Rest;Daniel Winzen;Stephan Bauer;Roland Berendes;Johann Meisner;T Thümmler;Sascha Wüstling;Christian Weinheimer;Thomas Thuemmler; |
| Journal | metrologia |
| Year | 2019 |
| DOI |
10.1088/1681-7575/ab2997
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.