Design and Analysis of a Combined Strain-Vibration-Temperature Sensor with Two Fiber Bragg Gratings and a Trapezoidal Beam.

Clicks: 324
ID: 114228
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #407 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A combined sensor to simultaneously measure strain, vibration, and temperature has been developed. The sensor is composed of two Fiber Bragg gratings (FBGs) and a vibration gainer. One FBG is used to measure strain, while the other measures vibration and temperature. The gainer has a mass block which is used to increase its sensitivity to vibration. The main beam of the vibration gainer was designed as a trapezoid in order to reduce the strain gradient while sensing vibration. In addition, an interrogation method was used to eliminate interactions between measured parameters. Experiments were carried out to analyze the performance of the proposed sensor. For individual strain measurement in the range of 0-152 με, the sensitivity and nonlinearity error were 1.878 pm/με and 2.43% Full Scale (F.S.), respectively. For individual temperature measurement in the range of 50-210 °C, the sensitivity and nonlinearity error were 29.324 pm/°C and 1.88% F.S., respectively. The proposed sensor also demonstrated a sensitivity of 0.769 pm/m·s-2 and nonlinearity error of 1.83% F.S. for vibration measurement in the range of 10-55 m/s2. Finally, simultaneously measuring strain, temperature, and vibration resulted in nonlinearity errors of 4.23% F.S., 1.89% F.S., and 2.23% F.S., respectively.
Reference Key
yang2019sensorsdesign Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kun Yao,Qijing Lin,Jiang Zhuangde,Na Zhao,G.D. Peng,Bian Tian,Wenyun Jia,Ping Yang;Kun Yao;Qijing Lin;Jiang Zhuangde;Na Zhao;G.D. Peng;Bian Tian;Wenyun Jia;Ping Yang;
Journal sensors
Year 2019
DOI
10.3390/s19163571
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.