Indication of Electromagnetic Field Exposure via RBF-SVM Using Time-Series Features of Zebrafish Locomotion.
Clicks: 301
ID: 113645
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
75.3
/100
301 views
244 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #461 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper introduces a novel model based on support vector machine with radial basis function kernel (RBF-SVM) using time-series features of zebrafish () locomotion exposed to different electromagnetic fields (EMFs) to indicate the corresponding EMF exposure. A group of 14 adult zebrafish was randomly divided into two groups, 7 in each group; the fish of each group have the novel tank test under a sham or real magnetic exposure of 6.78 MHz and about 1 A/m. Their locomotion in the tests was videotaped to convert into the x, y coordinate time-series of the trajectories for reforming time-series matrices according to different time-series lengths. The time-series features of zebrafish locomotion were calculated by the comparative time-series analyzing framework highly comparative time-series analysis (HCTSA), and a limited number of the time-series features that were most relevant to the EMF exposure conditions were selected using the minimum redundancy maximum relevance (mRMR) algorithm for RBF-SVM classification training. Before this, ambient environmental parameters (AEPs) had little effect on the locomotion performance of zebrafish processed by the empirical method, which had been quantitatively verified by regression using another group of 14 adult zebrafish. The results have demonstrated that the purposed model is capable of accurately indicating different EMF exposures. All classification accuracies can be 100%, and the classification precision of several classifiers based on specific parameters and feature sets with specific dimensions can reach higher than 95%. The speculative reason for this result is that the specified EMF has affected the zebrafish neural aspect, which is then reflected in their behaviors. The outcomes of this study have provided a new indication model for EMF exposures and provided a reference for the investigation of the impact of EMF exposure.
| Reference Key |
he2020indicationsensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | He, Yaqing;Tsang, Kim Fung;Kong, Richard Yuen-Chong;Chow, Yuk-Tak; |
| Journal | sensors |
| Year | 2020 |
| DOI |
E4818
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.