Reuse of Data Center Waste Heat in Nearby Neighborhoods: A Neural Networks-Based Prediction Model
Clicks: 308
ID: 113181
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
308 views
61 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #45 of 220 articles by views in energies
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 220 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper addresses the problem of data centers’ cost efficiency considering the potential of reusing the generated heat in district heating networks. We started by analyzing the requirements and heat reuse potential of a high performance computing data center and then we had defined a heat reuse model which simulates the thermodynamic processes from the server room. This allows estimating by means of Computational Fluid Dynamics simulations the temperature of the hot air recovered by the heat pumps from the server room allowing them to operate more efficiently. To address the time and space complexity at run-time we have defined a Multi-Layer Perceptron neural network infrastructure to predict the hot air temperature distribution in the server room from the training data generated by means of simulations. For testing purposes, we have modeled a virtual server room having a volume of 48 m3 and two typical 42U racks. The results show that using our model the heat distribution in the server room can be predicted with an error less than 1 °C allowing data centers to accurately estimate in advance the amount of waste heat to be reused and the efficiency of heat pump operation.
| Reference Key |
antal2019energiesreuse
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Marcel Antal;Tudor Cioara;Ionut Anghel;Radoslaw Gorzenski;Radoslaw Januszewski;Ariel Oleksiak;Wojciech Piatek;Claudia Pop;Ioan Salomie;Wojciech Szeliga;Antal, Marcel;Cioara, Tudor;Anghel, Ionut;Gorzenski, Radoslaw;Januszewski, Radoslaw;Oleksiak, Ariel;Piatek, Wojciech;Pop, Claudia;Salomie, Ioan;Szeliga, Wojciech; |
| Journal | energies |
| Year | 2019 |
| DOI |
10.3390/en12050814
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.