One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition
Clicks: 234
ID: 110795
2019
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
30.0
/100
232 views
17 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
We conducted a one-year prospective, multicenter study to assess clinical outcomes after implantation of segmented, rotationally asymmetric multifocal intraocular lenses (IOLs) with +1.5 diopters (D) near addition. In this phase III clinical trial, 120 eyes of 65 patients undergoing phacoemulsification and implantation of Lentis Comfort LS-313 MF15 (Oculentis GmbH) were included. The ophthalmological examinations were performed before and 1 day, 1 week, 1, 3, 6, 9, and 12 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were measured. A defocus curve was obtained and patients were asked about the severity of photic phenomena. Postoperative distance and intermediate visual acuity was excellent, with UDVA, CDVA, UIVA, and DCIVA of approximately 20/20, 20/16, 20/25, 20/25 were attained, respectively. The level of near visual acuity was lower; UNVA and DCNVA remained at around 20/60 and 20/70, respectively. The defocus curve indicated that postoperative uncorrected visual acuity of 20/25 and 20/40 was obtained at as close as 67 cm and 50 cm, respectively. Contrast sensitivity was within the normal range, with a minimal level of subjective symptoms and high patient satisfaction. The rotationally asymmetric multifocal IOLs with +1.5 D near addition provided excellent distance and intermediate vision, but near vision was not enough for reading small prints. Contrast sensitivity was high, with very low incidences of photic phenomena and a high level of patient satisfaction.
| Reference Key |
oshika2019scientificone-year
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Tetsuro Oshika;Hiroyuki Arai;Yoshifumi Fujita;Mikio Inamura;Yasushi Inoue;Toru Noda;Kazunori Miyata;Tetsuro Oshika;Hiroyuki Arai;Yoshifumi Fujita;Mikio Inamura;Yasushi Inoue;Toru Noda;Kazunori Miyata; |
| Journal | Scientific reports |
| Year | 2019 |
| DOI |
doi:10.1038/s41598-019-49524-z
|
| URL | |
| Keywords |
reconstruction
lens diseases
National Center for Biotechnology Information
NCBI
NLM
MEDLINE
pubmed abstract
nih
national institutes of health
national library of medicine
research support
non-u.s. gov't
Tetsuro Oshika
kazunori miyata
pmid:31511557
pmc6739307
doi:10.1038/s41598-019-49524-z
hiroyuki arai
|
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org