Cascade marker removal algorithm for thyroid ultrasound images.
Clicks: 412
ID: 110431
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
70.6
/100
412 views
267 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #2 of 14 articles by views in Medical & biological engineering & computing
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
During thyroid ultrasound diagnosis, radiologists add markers such as pluses or crosses near a nodule's edge to indicate the location of a nodule. For computer-aided detection, deep learning models achieve classification, segmentation, and detection by learning the thyroid's texture in ultrasound images. Experiments show that manual markers are strong prior knowledge for data-driven deep learning models, which interferes with the judgment mechanism of computer-aided detection systems. Aiming at this problem, this paper proposes cascade marker removal algorithm for thyroid ultrasound images to eliminate the interference of manual markers. The algorithm consists of three parts. First, in order to highlight marked features, the algorithm extracts salient features in thyroid ultrasound images through feature extraction module. Secondly, mask correction module eliminates the interference of other features besides markers' features. Finally, the marker removal module removes markers without destroying the semantic information in thyroid ultrasound images. Experiments show that our algorithm enables classification, segmentation, and object detection models to focus on the learning of pathological tissue features. At the same time, compared with mainstream image inpainting algorithms, our algorithm shows better performance on thyroid ultrasound images. In summary, our algorithm is of great significance for improving the stability and performance of computer-aided detection systems. Graphical Abstract During thyroid ultrasound diagnosis, doctors add markers such as pluses or crosses near nodule's edge to indicate the location of nodule. Manual markers are strong prior knowledge for data-driven deep learning models, which interferes the judgment mechanism of computer-aided diagnosis system based on deep learning. Markers make models overfit the specific labeling forms easily, and performs poorly on unmarked thyroid ultrasound images. Aiming at this problem, this paper proposes a cascade marker removal algorithm to eliminate the interference of manual markers. Our algorithm make deep learning models pay attention on nodules' features of thyroid ultrasound images, which make computer-aided diagnosis system performs good in both marked imaging and unmarked imaging.
| Reference Key |
ying2020cascademedical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ying, Xiang;Zhang, Yulin;Yu, Mei;Wei, Xi;Zhu, Jialin;Gao, Jie;Liu, Zhiqiang;Shen, Hongqian;Zhang, Ruixuan;Li, Xuewei;Yu, Ruiguo; |
| Journal | Medical & biological engineering & computing |
| Year | 2020 |
| DOI |
10.1007/s11517-020-02216-7
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.