Robust Finger Vein ROI Localization Based on Flexible Segmentation
Clicks: 266
ID: 110139
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.3
/100
266 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #897 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.
| Reference Key |
lu2013sensorsrobust
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yu Lu;Shan Juan Xie;Sook Yoon;Jucheng Yang;Dong Sun Park;Lu, Yu;Xie, Shan Juan;Yoon, Sook;Yang, Jucheng;Park, Dong Sun; |
| Journal | sensors |
| Year | 2013 |
| DOI |
10.3390/s131114339
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.