Determination of the Removal Efficiency of Linear Alkyl Benzene Sulphonate Acids (LAS) in Fixed Bed Aeration Tank and Conventional Activated Sludge
Clicks: 380
ID: 109824
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
75.1
/100
380 views
280 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #7 of 21 articles by views in آب و فاضلاب
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Linear Alkyl Benzene Sulphonate Acids (LAS) are one of the anionic surfactants that are produced and used in large quantities in different countries and find their way into the natural environment through sewer systems. These compounds may potentially cause environmental hazards in such surface waters as rivers. It is, therefore, necessary to remove as much of these compounds as possible by biological processes in wastewater treatment plants. For this purpose, four parallel biological reactors were constructed that used the conventional activated sludge and aeration tanks with fixed bed on the bench scale in order to evaluate the removal efficiency of LAS. The reactors were operated under conditions similar to domestic wastewater treatment plants. Parameters of interest were measured according to standard methods and ANOVA and T-test were used for the statistical analysis of the data. The results showed that aeration tanks with fixed beds yielded higher values of LAS and COD removal and air consumption compared to the conventional activated sludge system. It was shown that the two systems studied achieved LAS removal efficiencies of 96% and 94% for an influent LAS concentration of 5 mg/L. Further, it was found that the effluents from both systems satisfied water quality standards for discharge into surface waters (
| Reference Key |
ebrahimi2011determination
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ebrahimi, Asghar;Moghadas, Hossein Poor;Movahedian, Hossein;Amin, Mohammad Mehdi;Dastjerdi, Marziyeh Vahid;Hosseini, Elham; |
| Journal | آب و فاضلاب |
| Year | 2011 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.