Mercury removal from municipal secondary effluent with hydrous ferric oxide reactive filtration.

Clicks: 267
ID: 109812
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #13 of 24 articles by views in Water environment research : a research publication of the Water Environment Federation

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study evaluated the ability of hydrous ferric oxide reactive filtration (HFO-RF) to remove mercury (Hg) from municipal secondary effluent at four study sites. Pilot HFO-RF systems (136 m /day) at two sites demonstrated total Hg concentration removal efficiencies of 96% (inflow/outflow mean total Hg: 43.6/1.6  ng/L) and 80% (4.2/0.8 ng/L). A lightly loaded medium-scale HFO-RF system (950 m /day) had a concentration removal efficiency of 53% (0.98/0.46 ng/L) and removed 0.52 mg/day of total Hg and 2.2 μg/day of methyl-Hg. A full-scale HFO-RF system (11,400 m /day) yielded a total Hg concentration removal efficiency of 97% (87/2.7 ng/L) and removed an estimated 0.36 kg/year of Hg. Results suggest that the quality of secondary effluent, including dissolved organic matter content, affects achievable minimum total Hg concentrations in effluent from HFO-RF systems. Low HFO-RF effluent concentrations (<1 ng/L) can be expected when treating secondary effluent from suspended-growth biological treatment systems. PRACTITIONER POINTS: Trace levels of mercury in municipal secondary effluent can negatively impact receiving waters. Hydrous ferric oxide reactive filtration (HFO-RF) can remove mercury from municipal secondary effluent to levels below the Great Lakes Initiative discharge standard of 1.3 ng/L. Mercury removal to low concentrations (< 1 ng/L) using HFO-RF appears to be associated with secondary effluents with low dissolved organic matter content. HFO-RF can also remove total phosphorus and turbidity to low concentrations.
Reference Key
beutel2019mercurywater Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Beutel, Marc W;Dent, Stephen R;Newcombe, Remy L;Möller, Gregory;
Journal Water environment research : a research publication of the Water Environment Federation
Year 2019
DOI
10.1002/wer.1007
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.