Absorbance and EEM fluorescence of wastewater: Effects of filters, storage conditions, and chlorination.

Clicks: 306
ID: 109803
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #129 of 409 articles by views in Chemosphere

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 409 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aim of this study was to delineate sample handling procedures for accurate fluorescence and UV absorbance measurements of wastewater organic matter. Investigations were performed using different wastewater qualities, including primary, secondary and tertiary wastewater effluents, and a wastewater-impacted surface water. Filtration by 0.7 μm glass microfiber filter, 0.45 μm polyvinylidene fluoride (PVDF) membrane, 0.45 μm cellulose nitrate membrane, and 0.45 μm polyethersulfone (PES) syringe filter released manufacture impurities in water that affected fluorescence measurements. However, pre-washing of filter by Milli-Q water was able to eliminate these interferences. Different storage conditions were tested, including storage of filtered and unfiltered samples under different temperatures (25 °C, 4 °C, -20 °C). According to the obtained results, the best practice of wastewater samples preservation was sample filtration at 0.7/0.45 μm immediately after collection followed by storage at 4 °C. However, the time of storage that assured changes of these spectroscopic measurements that do not exceed the 10% of the original value was dependent on water quality and selected wavelengths (i.e., selected fluorescing organic matter component). As a general rule, it is advisable to perform fluorescence and UV absorbance measurements as soon as possible after collection avoiding storage times of filtered water longer than 2 days. Finally, addition of chlorine doses typical for wastewater disinfection mainly affected tryptophan-like components, where changes that exceed the 10% of the fluorescence intensity measured in the unchlorinated sample were observed even at very low doses (≥1 mg/L). On the contrary, tyrosine-like and humic-like components showed changes <10% at chlorine doses of 0.5-5 mg/L.
Reference Key
sgroi2020absorbancechemosphere Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Sgroi, Massimiliano;Gagliano, Erica;Vagliasindi, Federico G A;Roccaro, Paolo;
Journal Chemosphere
Year 2020
DOI
S0045-6535(19)32532-9
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.