Water quality index development for groundwater quality assessment of Greater Noida sub-basin, Uttar Pradesh, India

Clicks: 257
ID: 109746
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #11 of 14 articles by views in cogent engineering

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The water quality index (WQI) is an important parameter for determining the drinking water quality for the end users. The study for the same has been carried on the groundwater by collecting 47 groundwater samples from 25 blocks of Greater Noida city, India. In order to develop WQI the samples were subjected to a comprehensive physicochemical and biological analysis of 11 parameters such as pH, calcium, magnesium, chloride, nitrate, sulphate, total dissolved solids, fluorides, bicarbonate, sodium and potassium. Geographical information system has been used to map the sampling area. The coordinates in terms of latitude and longitude of the sampling locations were recorded with the help of global positioning system. Piper plots and cation–anion correlation matrix were plotted from the values obtained by the analysis of various parameters. The WQI index for the same has been calculated and the values ranged from 53.69 to 267.85. The WQI values from present study indicate the very poor quality water in the area dominated by industrial and construction activities. Poor water quality has been observed in commercial zone of the study area. The analysis reveals the fact that the ground water of the Greater Noida needs a degree of treatment before consumption and needs to be protected from further contamination.
Reference Key
singh2016watercogent Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Singh, Sajal;Hussian, Athar;
Journal cogent engineering
Year 2016
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.