Roll-over shape of a prosthetic foot: a finite element evaluation and experimental validation.
Clicks: 291
ID: 108945
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
291 views
21 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #11 of 14 articles by views in Medical & biological engineering & computing
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Prosthetic feet have generally been designed experimentally by adopting a trial-and-error technique. The objective of this research is to introduce a novel numerical approach for the a priori evaluation of the roll-over shape (ROS) of a prosthetic foot for application in its systematic design and development. The ROS was achieved numerically by employing a non-linear finite element model incorporating the augmented Lagrangian and multi-point constraint contact formulations, a hyperelastic material model and a higher-order strain definition. The Ottobock Solid Ankle Cushion Heel (SACH) foot was chosen to experimentally validate the numerical model. The geometry of the foot was evaluated from optical scans, and the material properties were obtained from uniaxial tensile, shear and volumetric compression tests. A new setup was designed for an improved experimental determination of the ROS, with the inclusion of an extended moment arm and variable loading. Error analysis of the radius of curvature of the ROS between the numerical and experimental results showed the percentage error to be 7.52%, thereby establishing the validity of the model. A numerical design model of this kind can be utilised to vary the input design parameters to arrive at a prosthetic foot with specified performance characteristics effectively and economically. Graphical abstract.
| Reference Key |
balaramakrishnan2020rollovermedical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Balaramakrishnan, Thirunindravur Mannan;Natarajan, Sundararajan;Srinivasan, Sujatha; |
| Journal | Medical & biological engineering & computing |
| Year | 2020 |
| DOI |
10.1007/s11517-020-02214-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.