Mechanical and structural properties of different types of human aortic atherosclerotic plaques.
Clicks: 287
ID: 107966
2020
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
9.3
/100
31 views
31 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Atherosclerotic plaques are characterized by structural heterogeneity affecting aortic behaviour under mechanical loading. There is evidence of direct connections between the structural plaque arrangement and the risk of plaque rupture. As a consequence of aortic plaque rupture, plaque components are transferred by the bloodstream to smaller vessels, resulting in acute cardiovascular events with a poor prognosis, such as heart attacks or strokes. Hence, evaluation of the composition, structure, and biochemical profile of atherosclerotic plaques seems to be of great importance to assess the properties of a mechanically induced failure, indicating the strength and rupture vulnerability of plaque. The main goal of the research was to determine experimentally under uniaxial loading the mechanical properties of different types of the human abdominal aorta and human aortic atherosclerotic plaques identified based on vibrational spectra (ATR-FTIR and FT-Raman spectroscopy) analysis and validated by histological staining. The potential of spectroscopic techniques as a useful histopathological tool was demonstrated. Three types of atherosclerotic plaques - predominantly calcified (APC), lipid (APL), and fibrotic (APF) - were distinguished and confirmed by histopathological examinations. Compared to the normal aorta, fibrotic plaques were stiffer (median of E for circumferential and axial directions, respectively: 8.15 MPa and 6.56 MPa) and stronger (median of σ for APLc = 1.57 MPa and APLa = 1.64 MPa), lipidic plaques were the weakest (median of σ for APLc = 0.76 MPa and APLa = 0.51 MPa), and calcified plaques were the stiffest (median of E for circumferential and axial directions, respectively: 13.23 MPa and 6.67 MPa). Therefore, plaques detected as predominantly lipid and calcified are most prone to rupture; however, the failure process reflected by the simplification of the stress-stretch characteristics seems to vary depending on the plaque composition.
| Reference Key |
kobielarz2020mechanicaljournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kobielarz, Magdalena;Kozuń, Marta;Gąsior-Głogowska, Marlena;Chwiłkowska, Agnieszka; |
| Journal | Journal of the mechanical behavior of biomedical materials |
| Year | 2020 |
| DOI |
S1751-6161(20)30391-X
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.