DNA enzyme mediated ratiometric fluorescence assay for Pb(II) ion using magnetic nanosphere-loaded gold nanoparticles and CdSe/ZnS quantum dots.
Clicks: 311
ID: 106360
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
311 views
25 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #38 of 75 articles by views in Mikrochimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Based on the inner filter effect mechanism of quantum dots, a ratiometric fluorescence nanoprobe was constructed for the determination of Pb(II) ion. Green emitting quantum dots conjugated with DNA substrate (DNA) acted as donors providing green fluorescence, while gold nanoparticles coupled with DNA enzyme (DNA) as acceptors quench the green fluorescence. Meanwhile, FeO nanosphere served as magnetic substrates to facilitate separation process and red fluorescence as an "inner rule" to eliminate the background signal. In the presence of Pb(II) ion, the DNA specifically recognize and capture Pb(II) ion with enhanced catalytic activity, which can cleave DNA and "turn on" the green fluorescence (I), while the red fluorescence (I) remained unchanged. In this way, the ratio of I/I reflects the Pb(II) ion in the system, enabling the quantitative and selective determination of Pb(II) ion over nine different metal ions. Under optimal conditions, the ratiometric fluorescence assay showed good linearity (R = 0.98) within the range 10 to 100 ng mL. The limit of detection (LOD) was calculated to be 1.79 pg mL (S/N = 3, n = 3, ±3.8%). The proposed fluorescence nanoprobe provides better sensitivity and accuracy than non-ratiometric signal evaluation for Pb(II) ion determination. Schematic representation of ratiometric fluorescence nanoprobe for Pb(II) ion detection using green fluorescence of I as "signal switch" and red fluorescence of I as "inner rule." Graphical abstract.
| Reference Key |
wu2020dnamikrochimica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wu, Long;Zhu, Lin;Ma, Jing;Li, Jinjie;Liu, Jiawei;Chen, Yiping; |
| Journal | Mikrochimica acta |
| Year | 2020 |
| DOI |
10.1007/s00604-020-04230-w
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.