Effect of Measurement of Dew Point Temperature in Moist Air on the Absorption Line at 1392.53 nm of Water Vapor
Clicks: 353
ID: 10608
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
64.2
/100
353 views
262 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #5 of 14 articles by views in international journal of optics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The HITRAN database (High-Resolution Transmission molecular absorption database) is an extremely helpful reference for selecting lines of molecular species. In the case of water vapor, a particular strong absorption line around λ ≈ 1392.5 nm is suitable for the detection of molecules, not only because of its high strength but also because it is well separated from the neighboring transitions, thus avoiding any overlap. First, we present the optical system that uses a distributed feedback (DFB) laser diode, emitting around λ ≈ 1392.5 nm with a power ≈ 3 mW and linewidth ≤ 10 MHz. For metrological needs, we are looking for a means to control the water vapor concentration in ambient air in near real time and especially when an optical chilled mirror hygrometer is used. The latter instrument is widely used due to its performance with regard to both accuracy and repeatability of measurements. Here, using the molecular absorption device the use of such an instrument is examined from the point of view of its impact on the measurement of relative humidity. This paper reports the measured frequency positions of the observed line at
| Reference Key |
n2019effectinternational
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Khelifa, N.;Khelifa, N.; |
| Journal | international journal of optics |
| Year | 2019 |
| DOI |
10.1155/2019/3424172
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.