Quantification of a cocrystal and its dissociated compounds in solid dosage form using transmission Raman spectroscopy.

Clicks: 323
ID: 105228
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #25 of 235 articles by views in Journal of pharmaceutical and biomedical analysis

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The performance of transmission Raman spectroscopy (TRS) for quantifying a cocrystal and its dissociation in solid dosage form was investigated. Some tablets containing 0%-20% (w/w) of a cocrystal of carbamazepine (CBZ)/succinic acid (SUC), 0%-4% of CBZ, 0%-4% of SUC, and 75%-99% of D-mannitol were prepared. The Raman spectra of these tablets were preprocessed using the standard normal variate (SNV) or multiplicative scatter correction (MSC) as well as the Savitzky Golay second derivative, and then, these were used to generate calibration models using partial least squares (PLS) regression. The performance of the model was superior when the MSC preprocessing spectra of the cocrystal between 200 and 1800 cm were used for calibration. The determination coefficient of the PLS calibration curve for the CBZ/SUC cocrystal between 200 and 1800 cm with MSC was 0.97, root mean square error of cross validation (RMSECV) was 1.16, and root mean square error of prediction (RMSEP) was 1.10. As in the case of the CBZ/SUC cocrystal, the performance of the model was superior when the MSC preprocessing spectra of CBZ and SUC between 200 and 1800 cm were used for calibration. These data suggest that TRS is useful for quantifying a cocrystal and its dissociation compounds in solid dosage forms.
Reference Key
koide2020quantificationjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Koide, Tatsuo;Takeuchi, Yuki;Otaki, Takashi;Yamamoto, Katsuhiko;Shimamura, Rie;Ohashi, Ryo;Inoue, Motoki;Fukami, Toshiro;Izutsu, Ken-Ichi;
Journal Journal of pharmaceutical and biomedical analysis
Year 2020
DOI
S0731-7085(19)31385-8
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.