Surface modified polypropylene pipette tips packed with a monolithic plug of adsorbent for high-throughput sample preparation.

Clicks: 237
ID: 104896
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #23 of 41 articles by views in journal of separation science

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
UV-initiated poly(butyl methacrylate-ethylene glycol dimethacrylate) porous polymer monoliths were prepared in situ in polypropylene-based pipette tips for high-throughput sample preparation. Prior to the in situ polymerization, the surface of the PP tips was modified. In this work, two different surface modification approaches were tested for this purpose. First the photoinitiator benzophenone was used to generate radicals at the surface of PP by hydrogen abstraction. In the second modification approach, a thin layer of a polymer was directly grafted to the surface. The effect of surface modification was measured by contact angle measurements of a drop of water at the surface. As a result of the surface modification, scan electron microscopy images indicate a covalent attachment of the monolith to the wall of the pipette tip. Pipette tips modified with 5% BP in methanol and packed with a plug of monolith were further evaluated for high-throughput sample preparation. Using a liquid handling system, the extraction performance of packed pipette tips was tested for the analysis of ropivacaine in plasma samples. The recovery and reproducibility results were in accordance with internationally accepted criteria for qualitative and quantitative analysis of the test substance, ropivacaine.
Reference Key
altun2007surfacejournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Altun, Zeki;Hjelmström, Anette;Abdel-Rehim, Mohamed;Blomberg, Lars G;
Journal journal of separation science
Year 2007
DOI
DOI not found
URL URL not found
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.