Um sistema de ventrículo pulmonar produzindo pressão pulsátil em único ventrículo: modelo experimental A pulmonary ventricle system producing pulsatile pressure in single ventricle: experimental model

Clicks: 268
ID: 104312
2006
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
OBJETIVO: Pacientes com ventrículo único funcional têm prognóstico ruim, que resulta em insuficiência cardíaca, mesmo após tratamento cirúrgico. As operações derivação cavo-pulmonar (exceto pelas conexões do átrio direito ao ventrículo direito) não apresentam sistema ventricular pulmonar com pressão pulsátil, além do fluxo reduzido ao ventrículo único. Para resolver o problema, tentamos criar um ventrículo pulmonar que produza pressão pulsátil experimentalmente. MÉTODO: Tentamos criar um sistema ventricular direito que produzisse pressão pulsátil. O modelo experimental foi realizado em seis ovelhas. As pressões do ventrículo pulmonar criado, da artéria pulmonar e do ventrículo esquerdo foram medidas após a saída da circulação extracorpórea. RESULTADOS: A média das pressões arteriais pulmonares sistólica e diastólica foi 15,6 ± 2,0 mmHg e 4,5 ± 1,5 mmHg. A média da pressão sistólica ventricular esquerda foi 76,6 ± 4,4 mmHg. CONCLUSÃO: Um ventrículo que produza pressão pulsátil é necessário para a regulação do fluxo da artéria pulmonar, com pressão venosa central e pressão pulmonar não pulsátil nas anomalias como ventrículos únicos funcionais.
OBJECTIVE: Patients with functional single ventricle show bad survey, most of which result in cardiac failure even in the case that they are operated. The right heart bypass operations except for right atrium and right ventricle connections lack pulsatile pulmonary ventricle system besides the volume lack coming to the common ventricle. To solve the problem, we tried to create a pulmonary ventricle which produces pulsatile pressure experimentally. METHODS: We tried to form a right ventricle system which produces pulsatile pressure. The experimental model was carried on six sheep. The pressures of the created pulmonary ventricle, pulmonary artery and the left ventricle were measured after leaving the cardiopulmonary bypass. RESULTS: The mean of the systolic and diastolic pulmonary artery pressures were 15,6 ± 2.0 mmHg and 4.5 ± 1.5 mmHg. The mean of the left ventricular systolic pressure was mean 76.6 ± 4.4 mmHg. CONCLUSION: A ventricle producing pulsatile pressure is necessary for regulating the pulmonary artery flow with high central venous pressure and low non-pulsatile pulmonary pressure in the anomalies with functional single ventricles.
Reference Key
emrecan2006umbrazilian Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Emrecan, Bilgein;Kestelli, Mert;Yilik, Levent;Lafçi, Banu;Özsöyler, Ibrahim;Gürbüz, Ali;Özbek, Cengiz;
Journal brazilian journal of cardiovascular surgery
Year 2006
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.