D-optimal design as a useful tool response surface methodology for the optimization of signals from synchronous fluorescence prior to simultaneous determination of avanafil and tadalafil.
Clicks: 256
ID: 103103
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
256 views
33 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #75 of 116 articles by views in spectrochimica acta part a, molecular and biomolecular spectroscopy
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A rapid, smart and sensitive first derivative spectrofluorimetric method has been carried out for the simultaneous estimation of avanafil and tadalafil either in their pure form, tablet dosage form or spiked human plasma. The measurements of normal emission spectra or synchronous fluorescence intensity of both drugs show severe overlap which hindered their determination using normal fluorescence or synchronous intensity. Therefore, a highly sensitive first derivative synchronous fluorescence procedure was used to resolve this overlap. The method is based upon measurement of the amplitude of the first derivative of synchronous fluorescence intensity of both drugs at Δλ = 70 nm and at suitable wavelength of 396 nm and 364 nm for avanafil and tadalafil, respectively. Under the optimum conditions, the linear determination ranges are 50-1800 and 5-400 ng mL with a detection limit of 12.93 and 1.46 ng mL for avanafil and tadalafil, respectively. A response surface methodology was used for optimization using D-optimal design which can be used for determination of the exact optimum parameters specifically designed for this method. In addition; it is a good way to graphically clarify the relationship between various experimental variables and the synchronous fluorescence intensity.
| Reference Key |
abdelraoof2020doptimalspectrochimica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Abdel-Raoof, Ahmed M;Said, Ragab A M;Emara, Mohamed S;El-Desouky, Ebrahim A;Abdelzaher, Ahmed M;Hasan, Mohamed A;Osman, Ayman E; |
| Journal | spectrochimica acta part a, molecular and biomolecular spectroscopy |
| Year | 2020 |
| DOI |
S1386-1425(20)30291-2
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.