Common-path dual-wavelength quadrature phase demodulation of EFPI sensors using a broadly tunable MG-Y laser.
Clicks: 212
ID: 102797
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
212 views
40 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #68 of 81 articles by views in Optics express
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A common-path dual-wavelength phase demodulation technique for extrinsic Fabry-Perot interferometric (EFPI) sensors is proposed on the basis of a broadly tunable modulated grating Y-branch (MG-Y) laser. It can address the three main concerns of existing dual-wavelength phase interrogation methods: the imbalances and disturbances caused by two optical paths utilizing two lasers or two photodetectors, the restrictions between two operating wavelengths and the cavity length of EFPI, and the difficulty in eliminating the direct current (DC) component of the interferometric fringe. Dual-wavelength phase interrogation is achieved in a common optical path through high-speed wavelength switching. Taking advantage of the MG-Y laser's full spectrum scanning ability (1527 ∼ 1567 nm), initial cavity length and DC component can be directly measured by white light interferometry. Two quadrature wavelengths are then selected to perform high speed phase demodulation scheme. Three polyethylene terephthalate (PET) diaphragm based EFPI acoustic sensors with cavity lengths of 127.954 µm, 148.366 µm and 497.300 µm, are used to demonstrate the effectiveness.
| Reference Key |
liu2019commonpathoptics
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liu, Qiang;Jing, Zhenguo;Li, Ang;Liu, Yueying;Huang, Zhiyuan;Zhang, Yang;Peng, Wei; |
| Journal | Optics express |
| Year | 2019 |
| DOI |
10.1364/OE.27.027873
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.