Clinical validation of a graphical method for radiation therapy plan quality assessment.
Clicks: 318
ID: 102204
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
318 views
44 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 3 articles by views in radiation oncology (london, england)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This work aims at clinically validating a graphical tool developed for treatment plan assessment, named SPIDERplan, by comparing the plan choices based on its scoring with the radiation oncologists (RO) clinical preferences.SPIDERplan validation was performed for nasopharynx pathology in two steps. In the first step, three ROs from three Portuguese radiotherapy departments were asked to blindly evaluate and rank the dose distributions of twenty pairs of treatment plans. For plan ranking, the best plan from each pair was selected. For plan evaluation, the qualitative classification of 'Good', 'Admissible with minor deviations' and 'Not Admissible' were assigned to each plan. In the second step, SPIDERplan was applied to the same twenty patient cases. The tool was configured for two sets of structures groups: the local clinical set and the groups of structures suggested in international guidelines for nasopharynx cancer. Group weights, quantifying the importance of each group and incorporated in SPIDERplan, were defined according to RO clinical preferences and determined automatically by applying a mixed linear programming model for implicit elicitation of preferences. Intra- and inter-rater ROs plan selection and evaluation were assessed using Brennan-Prediger kappa coefficient.Two-thirds of the plans were qualitatively evaluated by the ROs as 'Good'. Concerning intra- and inter-rater variabilities of plan selection, fair agreements were obtained for most of the ROs. For plan evaluation, substantial agreements were verified in most cases. The choice of the best plan made by SPIDERplan was identical for all sets of groups and, in most cases, agreed with RO plan selection. Differences between RO choice and SPIDERplan analysis only occurred in cases for which the score differences between the plans was very low. A score difference threshold of 0.005 was defined as the value below which two plans are considered of equivalent quality.Generally, SPIDERplan response successfully reproduced the ROs plan selection. SPIDERplan assessment performance can represent clinical preferences based either on manual or automatic group weight assignment. For nasopharynx cases, SPIDERplan was robust in terms of the definitions of structure groups, being able to support different configurations without losing accuracy.
| Reference Key |
ventura2020clinicalradiation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ventura, Tiago;Dias, Joana;Khouri, Leila;Netto, Eduardo;Soares, André;da Costa Ferreira, Brigida;Rocha, Humberto;Lopes, Maria do Carmo; |
| Journal | radiation oncology (london, england) |
| Year | 2020 |
| DOI |
10.1186/s13014-020-01507-5
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org