The low acute effectiveness of a high-power short duration radiofrequency current application technique in pulmonary vein isolation for atrial fibrillation.
Clicks: 397
ID: 101145
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
397 views
53 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #2 of 21 articles by views in cardiology journal
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Application of high power radiofrequency (RF) energy for a short duration (HPSD) to isolate pulmonary vein (PV) is an emerging technique. But power and duration settings are very different across different centers. Moreover, despite encouraging preclinical and clinical data, studies measuring acute effectiveness of various HPSD settings are limited.Twenty-five consecutive patients with symptomatic atrial fibrillation (AF) were treated with pulmonary vein isolation (PVI) using HPSD. PVI was performed with a contact force catheter (Thermocool SF Smart-Touch) and Carto 3 System. The following parameters were used: energy output 50 W, target temperature 43°C, irrigation 15 mL/min, targeted contact force of > 10 g. RF energy was applied for 6 to 10 s. Required minimal interlesion distance was 4 mm. Twenty minutes after each successful PVI adenosine provocation test (APT) was performed by administrating 18 mg adenosine to unmask dormant PV conduction.All PVs (100 PVs) were successfully isolated. RF lesions needed per patient were 131 ± 41, the average duration for each RF application was 8.1 ± 1.7 s. Procedure time was 138 ± 21 min and average of total RF energy duration was 16.3 ± 5.2 min and average amount of RF energy was 48209 ± 12808W s. APT application time after PVI was 31.1 ± 8.3 min for the left sided PVs and 22.2 ± 4.6 min (p = 0.005) for the right sided PVs. APT was transiently positive in 18 PVs (18%) in 8 (32%) patients.Pulmonary vein isolation with high power for 6-10 s is feasible and shortens the procedure and ablation duration. However, acute effectiveness of the HPSD seems to be lower than expected. Further studies combining other ablation parameters are needed to improve this promising technique.
| Reference Key |
ucer2020thecardiology
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ücer, Ekrem;Jungbauer, Carsten;Hauck, Christian;Kaufmann, Manuel;Poschenrieder, Florian;Maier, Lars;Fredersdorf, Sabine; |
| Journal | cardiology journal |
| Year | 2020 |
| DOI |
10.5603/CJ.a2020.0033
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.