Accuracy of computer-assisted vertical cup-to-disk ratio grading for glaucoma screening.

Clicks: 196
ID: 29300
2019
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
Glaucoma screening can be performed by assessing the vertical-cup-to-disk ratio (VCDR) of the optic nerve head from fundus photography, but VCDR grading is inherently subjective. This study investigated whether computer software could improve the accuracy and repeatability of VCDR assessment.In this cross-sectional diagnostic accuracy study, 5 ophthalmologists independently assessed the VCDR from a set of 200 optic disk images, with the median grade used as the reference standard for subsequent analyses. Eight non-ophthalmologists graded each image by two different methods: by visual inspection and with assistance from a custom-made publicly available software program. Agreement with the reference standard grade was assessed for each method by calculating the intraclass correlation coefficient (ICC), and the sensitivity and specificity determined relative to a median ophthalmologist grade of ≄0.7.VCDR grades ranged from 0.1 to 0.9 for visual assessment and from 0.1 to 1.0 for software-assisted grading, with a median grade of 0.4 for each. Agreement between each of the 8 graders and the reference standard was higher for visual inspection (median ICC 0.65, interquartile range 0.57 to 0.82) than for software-assisted grading (median ICC 0.59, IQR 0.44 to 0.71); P = 0.02, Wilcoxon signed-rank test). Visual inspection and software assistance had similar sensitivity and specificity for detecting glaucomatous cupping.The computer software used in this study did not improve the reproducibility or validity of VCDR grading from fundus photographs compared with simple visual inspection. More clinical experience was correlated with higher agreement with the ophthalmologist VCDR reference standard.
Reference Key
snyder2019accuracyplos Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Snyder, Blake M;Nam, Sang Min;Khunsongkiet, Preeyanuch;Ausayakhun, Sakarin;Leeungurasatien, Thidarat;Leiter, Maxwell R;Sevastopolsky, Artem;Joye, Ashlin S;Berlinberg, Elyse J;Liu, Yingna;Ramirez, David A;Moe, Caitlin A;Ausayakhun, Somsanguan;Stamper, Robert L;Keenan, Jeremy D;
Journal PloS one
Year 2019
DOI 10.1371/journal.pone.0220362
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.