intermittent misfiring default detection and localisation on a pwm inverter using wavelet decomposition

Clicks: 170
ID: 165817
2008
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
This paper presents a method to detect and localize intermittent misfiring default on a Pulse Width Modulation (PWM) inverter supplying a squirrel cage induction machine. The proposed method is based on the Discrete Wavelet Transform (DWT) technique to analyse stator current signals. The intermittent misfiring detection is performed thanks to the Daubechies wavelet mother in high frequency bands of the stator current signal. The localisation of the phase where the intermittent misfiring occurs is determined by a statistic approach. This approach is based on the computing of mean power characteristics of the detail signals which are obtained from the stator current wavelet decomposition.
Reference Key
sethom2008journalintermittent Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;H. Ben Attia Sethom;M. Ajabi Ghedamsi
Journal آب و فاضلاب