Permanent His-bundle (HB) pacing is usually accompanied by simultaneous capture of the adjacent right ventricular (RV) myocardium-this is described as a non-selective (ns)-HB pacing. It is of clinical importance to confirm HB capture using standard electrocardiogram (ECG). Our aim was to identify ECG criteria for loss of HB capture during ns-HB pacing.Patients with permanent HB pacing were recruited. Electrocardiograms during ns-HB pacing and loss of HB capture (RV-only capture) were obtained. Electrocardiogram criteria for loss/presence of HB capture were identified. In the validation phase, these criteria and the 'HB ECG algorithm' were tested using a separate, sizable set of ECGs. A total of 353 ECG (226 ns-HB and 128 RV-only) were obtained from 226 patients with permanent HB pacing devices. QRS notch/slur in left ventricular leads and R-wave peak time (RWPT) in lead V6 were identified as the best features for differentiation. The 'HB ECG algorithm' based on these features correctly classified 87.1% of cases with sensitivity and specificity of 93.2% and 83.9%, respectively. The criteria for definitive diagnosis of ns-HB capture (no QRS slur/notch in Leads I, V1, V4-V6, and the V6 RWPT ≤ 100 ms) presented 100% specificity.A novel ECG algorithm for the diagnosis of loss of HB capture and criteria for definitive confirmation of HB capture were formulated and validated. The algorithm might be useful during follow-up and the criteria for definitive confirmation of ns-HB capture offer a simple and reliable ancillary procedural endpoint during HB device implantation.
Reference Key |
jastrzbski2019electrocardiographiceuropace
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Jastrzębski, Marek;Moskal, Paweł;Curila, Karol;Fijorek, Kamil;Kukla, Piotr;Bednarek, Agnieszka;Kiełbasa, Grzegorz;Bednarski, Adam;Baranchuk, Adrian;Czarnecka, Danuta; |
Journal | Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology |
Year | 2019 |
DOI | euz275 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.