Energy-efficient FastICA implementation for biomedical signal separation.

Clicks: 137
ID: 55834
2011
This paper presents an energy-efficient fast independent component analysis (FastICA) implementation with an early determination scheme for eight-channel electroencephalogram (EEG) signal separation. The main contributions are as follows: (1) energy-efficient FastICA using the proposed early determination scheme and the corresponding architecture; (2) cost-effective FastICA using the proposed preprocessing unit architecture with one coordinate rotation digital computer-based eigenvalue decomposition processor and the proposed one-unit architecture with the hardware reuse scheme; and (3) low-computation-time FastICA using the four parallel one-units architecture. The resulting power dissipation of the FastICA implementation for eight-channel EEG signal separation is 16.35 mW at 100 MHz at 1.0 V. Compared with the design without early determination, the proposed FastICA architecture implemented in united microelectronics corporation 90 nm 1P9M complementary metal-oxide-semiconductor process with a core area of 1.221 × 1.218 mm2 can achieve average energy reduction by 47.63%. From the post-layout simulation results, the maximum computation time is 0.29 s.
Reference Key
van2011energyefficientieee Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Van, Lan-Da;Wu, Di-You;Chen, Chien-Shiun;
Journal IEEE Transactions on Neural Networks
Year 2011
DOI 10.1109/TNN.2011.2166979
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.