A novel wall water system for cardiopulmonary bypass may reduce the risk of aerosolized infection.
Clicks: 230
ID: 54684
2018
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
80.6
/100
230 views
184 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Oxygenators for cardiopulmonary bypass require water flow for their integral heat exchanger. Heater-cooler units are nearly universally used for this requirement. Heater-cooler units pose the risk of aerosolized infection. The Centers for Disease Control and Prevention recommended discontinuing use of Stöckert 3T heater-cooler units (LivaNova PLC, London, United Kingdom) in October 2016 because of this risk. We aimed to reduce the risk of aerosolized infection posed by heater-cooler units by eliminating those devices from our operating rooms.The cardiac surgery division collaborated with in-house specialties to engineer a novel wall water system. The design called for service to 4 operating rooms with the actual water mixing valve in an operating room closet. Remote temperature control was mounted next to the heart-lung machine. Primary safety systems built into the water system include 5 μm filtration, pressure regulating and relief valves, flow quantifiers, limits to the hot and chilled input temperatures, and a novel bridge near the heart-lung machine that allows the perfusionist to test the system before patient use and to quickly disconnect the patient in case of system malfunction. In addition, all water line connections can be made with the tubing drained and never under pressure.This novel wall water system has successfully provided heat exchanger water flow on 625 patients undergoing congenital heart surgery requiring cardiopulmonary bypass during its first 9 months of use.Wall water systems are an option for oxygenator heat exchangers that allow for improved heat exchange performance while reducing the risk of heater-cooler unit-associated infection during cardiac surgery.Reference Key |
matte2018athe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Matte, Gregory S;Sandora, Thomas J;Howe, Robert J;Regan, William L;Potter-Bynoe, Gail;Neal, James R;Del Nido, Pedro J; |
Journal | The Journal of thoracic and cardiovascular surgery |
Year | 2018 |
DOI | S0022-5223(18)30618-4 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.